USBio Logo

026853 Monocyte Chemotactic Protein 1 (MCP1) BioAssay™ ELISA Kit (Rat)

Specifications
Brand
BioAssay™
Specificity
Rat
Kit Type
Sandwich ELISA
Tests
96
Sample Volume
100ul
Sensitivity
0.061ng/ml
Detection Method
Colorimetric
Detection Range
0.156-10ng/ml
Sample Matrix
serum, plasma, tissue culture
EU Commodity Code
38220000
UN DOT Shipping
UN2796 PGII
Shipping Temp
Blue Ice
Storage Temp
4°C/-20°C

Monocyte Chemotactic Protein 1 (MCP1) BioAssay™ ELISA Kit (Rat) is a sandwich enzyme immunoassay for in vitro quantitative measurement of MCP1 in rat serum, plasma, tissue homogenates, cell culture supernates and other biological fluids.

Detection Range
0.156-10ng/ml
Sensitivity
0.061ng/ml
Intra-Assay
CV < 10%
Inter-Assay
CV < 12%
Kit Components
*026853A: Microtiter Plate, 1x96 wells, Pre-coated, ready to use *026853B: Standard, 2x1 vial  026853C: Standard Diluent, 1x20ml *026853D: Detection Reagent A (100X), 1x120ul  *026853E: Detection Reagent B (100X), 1x120ul  026853F: Assay Diluent A (2X), 1x6ml 026853G: Assay Diluent B (2X), 1x6ml 026853H: TMB Substrate, 1x9ml *026853J: Positive Control, 99.3pg/ml, 1x1 vial 026853K: Stop Solution, 1x6ml 026853L: Wash Buffer, 30X, 1x20ml
Precaution
The Stop Solution (026853K) suggested for use with this kit is an acid solution. Wear eye, hand, face, and clothing protection when using this material.
Storage and Stability
Store *026853A, *026853B, *026853D, *026853E and *026853J at -20°C. After reconstitution of *026853J, store at 4°C and use within 5 days. Store all the other components at 4°C. Unused kit is stable for 6 months. Once kit components are opened, it is highly recommended to use remaining reagents within 1 month provided this is within the expiration date of the kit. For maximum recovery of product, centrifuge the original vials after thawing and prior to removing the cap.
Assay Procedure Summary
1. Prepare all reagents, samples and standards; 2. Add 100ul standard or sample to each well. Incubate 2 hours at 37°C. 3. Add 100ul working Detection Reagent A immediately. Incubate 1 hour at 37°C. 4. Aspirate and wash 3 times. 5. Add 100ul working Detection Reagent B. Incubate 30 minutes at 37°C. 6. Aspirate and wash 5 times. 7. Add 90ul TMB Substrate. Incubate 15-25 minutes at 37°C. 8. Add 50ul Stop Solution. Read at 450nm immediately.
Pricing
Order
Proceed to Checkout
Cart Summary
ProductSizeListYour PriceQtyExt Price
Subtotal:Subtotal:
Subtotal:Subtotal:
Total Coupon Savings:Total Coupon Savings:()
Your cart is currently empty.
- Coupon Code
Recently Viewed
  • Contact Us

    Visit our technical library or contact our support staff to answer your questions.

    Telephone:
    1-800-520-3011

    Library | Contact

    Distributors

    For customers outside of the United States, please use one of our many distributors.

    View Distributors

    Payment Methods

    We accept the following payment methods as well as pay-by-invoice.

    MasterCard Visa PayPal
    © 2023-2024 United States Biological - All Rights Reserved