Technical Data

124515-ML490
Grade
Affinity Purified
Accession Number
BC017276, AAH17276
EU Commodity Code
30021010
Shipping Temp
Blue Ice
Storage Temp
4°C Do Not Freeze
Notes
Preservative Free
CD106 (CD106 Antigen, DKFZp779G2333, INCAM 100, INCAM-100, L1CAM, MGC99561, Vascular Cell Adhesion Molecule 1, VCAM 1, VCAM1, VCAM-1, Vascular Cell Adhesion Protein 1) (MaxLight 490)

MaxLight™490 is a new Blue-Green photostable dye conjugate comparable to DyLight™488, Alexa Fluor™488 and offers better labeling efficiency, brighter imaging and increased immunodetection. Absorbance (491nm); Emission (515nm); Extinction Coefficient 73,000.

VCAM-1, which is present on activated endothelial cells. VCAM-1 is an adhesion molecule, which binds to the integrin alpha4/beta1 (VLA-4) and to the integrin alpha4/beta7 on lymphocytes. This antibody has been shown to inhibit T lymphocyte adhesion to TNF stimulated endothelial cells. The molecular weight of the recognized antigen is 110kD.
Applications
Suitable for use in FLISA and Western Blot. Other applications not tested.
Recommended Dilution
Optimal dilutions to be determined by the researcher.
AA Sequence
MPGKMVVILGASNILWIMFAASQAFKIETTPESRYLAQIGDSVSLTCSTTGCESPFFSWRTQIDSPLNGKVTNEGTTSTLTMNPVSFGNEHSYLCTATCESRKLEKGIQVEIYSFPKDPEIHLSGPLEAGKPITVKCSVADVYPFDRLEIDLLKGDHLMKSQEFLEDADRKSLETKSLEVTFTPVIEDIGKVLVCRAKLHIDEMDSVPTVRQAVKELQVYISPKNTVISVNPSTKLQEGGSVTMTCSSEGLPAPEIFWSKKLDNGNLQHLSGNATLTLIAMRMEDSGIYVCEGVNLIGKNRKEVELIVQEKPFTVEISPGPRIAAQIGDSVMLTCSVMGCESPSFSWRTQIDSPLSGKVRSEGTNSTLTLSPVSFENEHSYLCTVTCGHKKLEKGIQVELYSFPRDPEIEMSGGLVNGSSVTVSCKVPSVYPLDRLEIELLKGETILENIEFLEDTDMKSLENKSLEMTFIPTIEDTGKALVCQAKLHIDDMEFEPKQRQSTQTLYVNVAPRDTTVLVSPSSILEEGSSVNMTCLSQGFPAPKILWSRQLPNGELQPLSENATLTLISTKMEDSGVYLCEGINQAGRSRKEVELIIQVTPKDIKLTAFPSESVKEGDTVIISCTCGNVPETWIILKKKAETGDTVLKSIDGAYTIRKAQLKDAGVYECESKNKVGSQLRSLTLDVQGRENNKDYFSPELLVLYFASSLIIPAIGMIIYFARKANMKGSYSLVEAQKSKV
Storage and Stability
Store product at 4°C in the dark. DO NOT FREEZE! Stable at 4°C for 12 months after receipt as an undiluted liquid. Dilute required amount only prior to immediate use. Further dilutions can be made in assay buffer. Caution: MaxLight™490 conjugates are sensitive to light. For maximum recovery of product, centrifuge the original vial prior to removing the cap.
Note: Applications are based on unconjugated antibody.

Intended for research use only. Not for use in human, therapeutic, or diagnostic applications.

References
No references available
USBio References
No references available
United States Biological | 4 Technology Way | Salem, MA 01970
Phone 800-520-3011 | Fax 978-594-8052 | Website www.usbio.net