Technical Data

517034
Kit Type
Sandwich ELISA
Tests
96
Sample Volume
50ul
Sensitivity
0.058ng/ml
Detection Method
Colorimetric
Detection Range
0.156-10ng/ml
Sample Matrix
Tissue homogenates, cell lysates and other biological fluids
EU Commodity Code
38220000
UN DOT Shipping
UN2796 PGII
Shipping Temp
Blue Ice
Storage Temp
4°C/-20°C
BMP Binding Endothelial Regulator (BMPER) BioAssay™ ELISA Kit (Rat)
Cv2; CRIM3; Crossveinless-2; Bone morphogenetic protein-binding endothelial cell precursor-derived regulator
Sample Type
Tissue homogenates, cell lysates and other biological fluids
Intended Use
The kit is a sandwich enzyme immunoassay for in vitro quantitative measurement of BMPER in rat tissue homogenates, cell lysates and other biological fluids.
Sensitivity
0.058ng/ml
Range
0.156-10ng/ml
Specificity
This assay has high sensitivity and excellent specificity for detection of BMP Binding Endothelial Regulator (BMPER). No significant cross-reactivity or interference between BMP Binding Endothelial Regulator (BMPER) and analogues was observed.
Precision
Intra-Assay: CV<10% Inter-Assay: CV<12%
Test Principle
The microtiter plate provided in this kit has been pre-coated with an antibody specific to BMPER. Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to BMPER. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain BMPER, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of BMPER in the samples is then determined by comparing the O.D. of the samples to the standard curve.
Kit Components
96-well strip plate, 1x Plate Standard, 2x vial Detection Reagent A, 1×120ul Detection Reagent B, 1×120ul TMB Substrate, 1×9ml Wash Buffer (30X), 1×20ml Standard Diluent, 1×20ml Assay Diluent A, 1×12ml Assay Diluent B, 1×12ml Stop Solution, 1x6ml
Storage and Stability
Store all components at 4°C. Stable for 6 months after receipt. For maximum recovery of product, centrifuge the original vial after thawing and prior to removing the cap.

Intended for research use only. Not for use in human, therapeutic, or diagnostic applications.

References
No references available
USBio References
No references available
United States Biological | 4 Technology Way | Salem, MA 01970
Phone 800-520-3011 | Fax 978-594-8052 | Website www.usbio.net