Technical Data

517427
Kit Type
Sandwich ELISA
Tests
96
Sample Volume
50ul
Sensitivity
0.59ng/ml
Detection Method
Colorimetric
Detection Range
1.56-100ng/ml
Sample Matrix
Serum, plasma, tissue homogenates and other biological fluids
EU Commodity Code
38220000
UN DOT Shipping
UN2796 PGII
Shipping Temp
Blue Ice
Storage Temp
4°C/-20°C
Matrix Metalloproteinase 2 (MMP2) BioAssay™ ELISA Kit (Equine) (Wide Range)
Sample Type
Serum, plasma, tissue homogenates and other biological fluids
Intended Use
The kit is a sandwich enzyme immunoassay for in vitro quantitative measurement of MMP2 in equine serum, plasma, tissue homogenates and other biological fluids.
Sensitivity
0.59ng/ml
Range
1.56-100ng/ml
Specificity
This assay has high sensitivity and excellent specificity for detection of Wide-range Matrix Metalloproteinase 2 (MMP2). No significant cross-reactivity or interference between Wide-range Matrix Metalloproteinase 2 (MMP2) and analogues was observed.
Precision
Intra-Assay: CV<10% Inter-Assay: CV<12%
Test Principle
The microtiter plate provided in this kit has been pre-coated with an antibody specific to MMP2. Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to MMP2. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain MMP2, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of MMP2 in the samples is then determined by comparing the O.D. of the samples to the standard curve.
Kit Components
96-well strip plate, 1x Plate Standard, 2x vial Detection Reagent A, 1×120ul Detection Reagent B, 1×120ul TMB Substrate, 1×9ml Wash Buffer (30X), 1×20ml Standard Diluent, 1×20ml Assay Diluent A, 1×12ml Assay Diluent B, 1×12ml Stop Solution, 1×6ml
Storage and Stability
Store all components at 4°C. Stable for 6 months after receipt. For maximum recovery of product, centrifuge the original vial after thawing and prior to removing the cap.

Intended for research use only. Not for use in human, therapeutic, or diagnostic applications.

References
No references available
USBio References
No references available
United States Biological | 4 Technology Way | Salem, MA 01970