I1904-14U8 Mouse Anti-IgG, Murine Isotype Control (PE/Cy7)

Specifications
Clone Type
Monoclonal
Host
Mouse
Conjugate
PE/Cy7
Isotype
IgG
Grade
Purified
Applications
FC FLISA
Shipping Temp
Blue Ice
Storage Temp
-20°C

Isotype controls are a type of negative control designed to measure the level of non-specific background signal caused by primary antibodies, based upon the tissue type of the sample. Non-specific binding of primary antibodies are typically caused by the following reasons
• Non-specific Fc receptor binding to cells  • Non-specific antibody interactions with cellular proteins or fluorochromes • Non-specific binding of the antibody or fluorochromes to cellular components  • Cell autofluorescence
Usually, the background signal is the result of immunoglobulins binding non-specifically to Fc receptors present on the cell surface. For example, antibodies raised in mice, particularly those of the IgG2a isotype, will bind strongly to some human leukocytes regardless of the test antibody specificity. In this case you would need a mouse IgG2a isotype control for use with human cells or tissues. Isotype controls are most commonly used in flow cytometry experiments, but may also be used in immunohistochemistry. 
Selecting an Isotype Control
Typically, an isotype control is matched to the host species and isotype of your specific primary antibody, the heavy chain (IgA, IgG, IgD, IgE, or IgM), subclass and light chain (kappa, lambda) class of the primary antibody;  the same fluorochrome (PE, APC, etc.), and have the same F:P ratio. F:P is a measurement of how many fluorescent molecules are present on each antibody.
When using directly labeled primary antibodies, it is also necessary to make sure that the isotype control is conjugated to the same fluorochrome or label as the test antibody. It is not sufficient to use one with a spectrally similar fluorochrome.
Non-specific Binding
To avoid non-specific binding, you also need to block Fc receptors on cell types, such as spleen cells, with FcR blocking reagents. Isotype controls should be used at the same concentration/dilution as the primary antibody. Isotype controls are mainly used to determine if the staining is real. Apart from isotype controls, unstained cells should always be included in the experimental set-up to monitor autofluorescence.
Applications for Isotype Controls
Although isotype controls are mainly used in flow cytometry, they can be used as standard blocking agents and protein coating agents for other applications including immunofluorescence, immunocytochemistry, western blotting, and ELISA.
Source
Normal mouse serum
Applications
• Flow cytometry • Enzyme-Linked-Immunosorbent-Assay (FLISA)
Recommended Dilution
Flow Cytometry: ≤ 0.2ug/10e6 cells Optimal dilutions to be determined by the researcher.
Storage and Stability
May be stored at 4°C for short-term only. For long-term storage and to avoid repeated freezing and thawing, aliquot and add glycerol (40-50%). Store at -20°C or colder. Aliquots are stable for at least 6 months at -20°C. For maximum recovery of product, centrifuge the original vial after thawing and prior to removing the cap. Further dilutions can be made in assay buffer.
Form
Supplied as a liquid in PBS, 0.09% sodium azide and a stabilizing agent. Labeled with PE/Cy7.
Purity
Purified
Conjugates
Pricing
Order
Proceed to Checkout
Cart Summary
ProductSizeListYour PriceQtyExt Price
Subtotal:Subtotal:
Subtotal:Subtotal:
Total Coupon Savings:Total Coupon Savings:()
Your cart is currently empty.
- Coupon Code
Recently Viewed
Contact Us

Visit our technical library or contact our support staff to answer your questions.

Telephone:
1-800-520-3011

Library | Contact

Distributors

For customers outside of the United States, please use one of our many distributors.

View Distributors

Payment Methods

We accept the following payment methods as well as pay-by-invoice.

MasterCard Visa PayPal
© 2023-2024 United States Biological - All Rights Reserved