USBio Logo

348744 genesig Real-Time PCR Detection Kit for Anaplasma phagocytophilum (Major Surface Protein 4 (msp4) Gene), Advanced

Specifications
Kit Type
PCR
Tests
150
Sample Volume
10ul
Sensitivity
10-100 copies
Detection Method
Fluorescent
Sample Matrix
Unlimited
EU Commodity Code
38220000
Shipping Temp
RT
Storage Temp
-20°C
Path-A.phagocytophilum Advanced

The genesig® Kit for for Anaplasma phagocytophilum (A.phagocytophilum) genomes is designed for the in vitro quantification of A. phagocytophilum genomes. The kit is designed to have the broadest detection profile possible whilst remaining specific to the A. phagocytophilum genome. The primers and probe sequences in this kit have 100% homology with a broad range of A. phagocytophilum sequences based on a comprehensive bioinformatics analysis.

PRODUCT MANUAL
http://www.genesig.com/assets/files/a_phagocytophilum.pdf
Product features
• Exceptional value for money • Rapid detection of all clinically relevant subtypes • Positive copy no. standard curve for quantification • Highly specific detection profile • High priming efficiency • Broad dynamic detection range (>6 logs) • Sensitive to < 100 copies of target • Accurate controls to confirm findings
ADVANCED KIT COMPONENTS
• A. phagocytophilum specific primer/probe mix (150 reactions; BROWN); FAM labeled • A. phagocytophilum positive control template (for Standard curve; RED) • Internal extraction control primer/probe mix (150 reactions; BROWN); VIC labeled as standard • Internal extraction control DNA (150 reactions; BLUE) • Endogenous control primer/probe mix (150 reactions; BROWN); FAM labeled • RNAse/DNAse free water (WHITE) for resuspension of primer/probe mixes • Template preparation buffer (YELLOW) for resuspension of internal control template, positive control template and standard curve preparation
KIT STORAGE AND STABILITY
This kit is stable at room temperature but should be stored at -20°C on arrival. Once the lyophilised components have been resuspended they should not be exposed to temperatures above -20°C for longer than 30 minutes at a time and unnecessary repeated freeze/thawing should be avoided. The kit is stable for six months from the date of resuspension under these circumstances. If a standard curve dilution series is prepared this can be stored frozen for an extended period. If you see any degradation in this serial dilution a fresh standard curve can be prepared from the positive control. We do not recommend using the kit after the expiry date stated on the pack.
REAGENTS AND EQUIPMENT TO BE SUPPLIED BY THE USER
• Real-Time PCR Instrument • DNA extraction kit This kit is recommended for use with genesig Easy. DNA/RNA Extraction Kit. However, it is designed to work well with all processes that yield high quality DNA with minimal PCR inhibitors. • oasigTM lyophilized or Precision Plus 2X qPCR Master Mix. This kit is intended for use with oasig or PrecisionPLUS 2X qPCR Master Mix. • Pipettors and Tips • Vortex and centrifuge • Thin walled 1.5 ml PCR reaction tubes
SUITABLE SAMPLE MATERIAL
All kinds of sample material suited for PCR amplification can be used. Please ensure the samples are suitable in terms of purity, concentration, and DNA integrity (An internal PCR control is supplied to test for non specific PCR inhibitors). Always run at least one negative control with the samples. To prepare a negative-control, replace the template DNA sample with RNase/DNase free water.
DYNAMIC RANGE OF TEST
Under optimal PCR conditions genesig® etection kits have very high priming efficiencies of >95% and can detect less than 100 copies of target template.
INSTRUMENTATION REQUIREMENTS
Designed for use with real-time PCR instruments. For use in genesig® q16, look for the “Easy” kit.
ABOUT THE genesig® KITS
genesig® kits are sold for research use only and are not licensed for diagnostic procedures.
Nucleic acid testing (NAT) is the method of choice for detection and quantification of a wide range of micro organisms. Primerdesign manufactures and supplies high quality quantitative Real-Time PCR kits for the detection and simultaneous quantification of numerous significant pathogens. A copy number standard curve is provided for quantification and an the internal extraction template (DNA or RNA), controls for the quality of the nucleic acid extraction and eliminates false negative results.
The kit is designed with the broadest possible detection profile to ensure that all clinically relevant strains and subtypes are detected. Target sequences are selected by working with data from key opinion leaders in the field. Multiple sequence alignments and unprecedented Real-Time PCR expertise in design and validation ensure the best possible kit. 
Details of the target and priming specificity are included in the individual handbooks above. Packaged, optimized and ready to use.
DNA/RNA EXTRACTION
genesig® Easy DNA/RNA extraction kits (sold separately) are a simple to use, low cost and powerful extraction technology suitable for virtually all sample types.
Pricing
Order
Proceed to Checkout
Cart Summary
ProductSizeListYour PriceQtyExt Price
Subtotal:Subtotal:
Subtotal:Subtotal:
Total Coupon Savings:Total Coupon Savings:()
Your cart is currently empty.
- Coupon Code
Recently Viewed
  • Contact Us

    Visit our technical library or contact our support staff to answer your questions.

    Telephone:
    1-800-520-3011

    Library | Contact

    Distributors

    For customers outside of the United States, please use one of our many distributors.

    View Distributors

    Payment Methods

    We accept the following payment methods as well as pay-by-invoice.

    MasterCard Visa PayPal
    © 2023-2024 United States Biological - All Rights Reserved